The constant temperature and humidity test chamber shall be regularly maintained during use. The condenser of the refrigeration system shall be regularly cleaned. The moving parts shall be lubricated according to the instructions, and the electrical control system shall be regularly maintained and inspected. These tasks are indispensable. In addition, Xiao Bian on the constant temperature and humidity test chamber to determine and eliminate common faults, summarize the following points for your reference.

1. When the temperature and humidity test box suddenly fails during the test operation, the control instrument will display a corresponding fault display prompt and a voice alarm. The operator can quickly check which type of fault belongs to in the troubleshooting section of the equipment operation and use it, and then the professional can quickly troubleshoot the fault to ensure the normal operation of the test. Other environmental testing equipment will have other phenomena in use, so specific phenomena should be analyzed and eliminated. In the high temperature test, if the temperature does not reach the test temperature, the electrical system can be checked and the faults can be eliminated one by one. If the temperature rises very slowly, it is necessary to look at the air circulation system and see if the adjustment baffle of the air circulation is normally open. Conversely, check whether the motor operation of the air circulation is normal. If the temperature overshoots badly, then you need to set the PID setting parameters. If the temperature rises directly, over-temperature protection, then the controller fails and the control instrument must be replaced.

2. During the humidity and heat test in the constant temperature and humidity test chamber, the actual humidity will reach 100% or the actual humidity and the target humidity will differ greatly. The value is much lower. The former phenomenon may be caused by dry gauze on the wet ball sensor. It is necessary to check whether the water tank in the wet ball sensor is short of water. The water level in the water tank is automatically controlled by a water level controller. Check whether the water supply system of the water level controller is normal and whether the water level controller is working properly. Another possibility is that the wet ball gauze may cause the gauze to become hard due to the long use time or the purity of the water supply, so that the gauze cannot absorb moisture and dry, and the above phenomenon can be eliminated only by replacing or cleaning the gauze. The latter phenomenon is mainly because the humidification system is not working. Check the water supply system of the humidification system. Whether there is a certain amount of water in the water supply system. Control whether the water level of the humidifying boiler water level is normal and whether the water level in the humidifying boiler is normal. If all of the above is normal, then check the electrical control system, which requires professional maintenance personnel to perform maintenance.

3, constant temperature and humidity test chamber low temperature can not reach the test index, then you have to observe the temperature changes, the temperature drop is very slow, or the temperature rises after a certain temperature, the former must check, do Whether the studio is to be dried before the low temperature test, so that the studio is kept dry, and then the test sample is placed in the work chamber and then tested. Whether the test sample in the work chamber is placed excessively, the wind in the work chamber cannot be fully circulated, and is eliminated. After the above reasons, it is necessary to consider whether it is a fault in the refrigeration system. In this case, it is necessary to ask the factory's professionals to perform the inspection. The latter phenomenon is caused by the poor use environment of the equipment. The ambient temperature of the equipment and the location of the equipment (the distance between the cabinet and the wall) must meet the requirements (both are specified in the equipment operating instructions).

Potato Chips/2D pellet Process Line

Potato Chips Process Line,French Fries Machine,Cassava Chips Crisps Process Machine,Sweet Potato Chips Machine

JINAN CFC MACHINERY CO.,LTD , https://www.cfcmachine.com

Posted on