Model NO.: SDC2-200
Certification: RoHS, ISO, UL, CCC
Condition: New
Max Cooling Capacity: 200W
Max Heating Capacity: 200W
Rated Power: 450W
Working Voltage: DC48V
Max Current: 8.5A
Working Temperature: -20 to 55 Degrees Celsius
Working Humidity: 10~95% Rh
Dimension: 400*285*250mm
Weight: 9kg
Protection Class: IP55
Trademark: Sanda
Transport Package: Standard Package
Specification: 400*285*250mm
Origin: China
HS Code: 8541500000

Outdoor advertising machine cooling system

Description

SANDA's 200 W DC solid state air conditioner models are designed to cool your electronic and electrical controls, instruments, computer terminals, printers, telecommunications equipment, surveillance devices, cameras, laser and optical equipment, and many other electronics in a variety of environments. Our electronic cabinet cooler is designed for use with a wide range of enclosures and transit cases. Models are available for both indoor and outdoor use in DC power configurations. Coolers feature corrosion-resistant stainless steel construction. All are available with a variety of options.

Outdoor Advertising Machine Cooling System

 

Features: 

• Extremely reliable solid state construction with long lifespan

• Maintenance free design with no moving components (other than fans)

• No compressor, refrigerant or filters

• Compact size, lightweight, convenient to install and operate

• Construction (Type 304 stainless steel) for indoor or outdoor use

• Standard models to 55°C (High ambient models avail.)

• Flush-mount or recessed-mount installation

• Recommended for vertical mounting only

• DC power configurations

• Complete 12 month warranty

Optional features:

• Supplemental heating capability

• Condensate drip pan with fittings and drain tubing

• Extension frame for flush mounting on outside of cabinet

• Rain shroud - vertical mount

• AC power supply (220VAC)

• Digital temperature controller (remote mount)

• Powder coated aluminum construction

Technical Data

No

Parameters

Model No.

SDC2-200

SDC2-300

1

Cooling capacity

W

200

300

2

Heating capacity

W

200

300

3

Rated voltage

V

DC48

4

Rated power

W

450

600

5

Rated current

A

8.5

13.6

6

Internal circulation air flow rate

m3/h

350

360

7

External circulation air flow rate

m3/h

         600

         640

 

8

 

Working range

°C

-20~55

RH

10%~95%

9

Cooling/Heating

Cooling and heating intelligent exchanging

10

 Protection class

IP55

 

 11

 

Dimension

Width

 

mm

250

250

Depth

285

285

Height

400

400

12

Noise

dB(A)

 60

60


Working Principle
Outdoor Advertising Machine Cooling System

How to install?


A. Embedded the door mounted TEC air conditioner into the open hole from the outside of the cabinet to ensure the TEC air conditioner's mounting flange match the cabinet's installation position.

B. Use 16* M4 phillips screws sequentially align the mounting holes on the mounting flange to fix and tighten it.

C. Check the mechanical installation of the cabinet TEC air conditioner, and do electrical installation after determining correct.


Application

Outdoor Advertising Machine Cooling System

Company Information

Your Advantages with Sanda Electronic:

1) ISO 9001:2008 audited factory, Patented design

2) 12 years R&D and manufacturing experience for dehumidifier; Cabinet air conditioner; Protection relay; Digital Meter; Temperature and humidity controller etc

3) ODM and OEM are warmly welcomed

4) Quality guarantee, 1 year warranty

5) 7/24h service, better pre-sale and after-sale service.

6) Professional suggestions, help you realize your goals and boost your sustainable development.
Outdoor Advertising Machine Cooling System

SANDA Certifications
Outdoor Advertising Machine Cooling System

 
SANDA Customers
Outdoor Advertising Machine Cooling System

Geothermal Ground Source Heat Pump

Introduction to GENT geothermal ground source heat pump

Ground source heat pump is a kind of high-efficiency, energy-saving and environmentally friendly heat pump, which is widely used in the fields of construction, industry and energy.

Advantages of geothermal heating and cooling unit

1. High efficiency and energy saving: The energy efficiency ratio of geothermal Air Conditioning is relatively high, which is much higher than traditional cogeneration and other technologies.

2. Environmentally friendly: geothermal heat pump air conditioning use the natural constant temperature cooling and heating sources contained in the surface or underground, reducing dependence on fossil fuels and reducing greenhouse gas emissions.

3. Easy maintenance: The maintenance cost of ground heat pump is low, and the heat pump and geothermal circulation system only need regular inspection and cleaning.

4. Strong adaptability: Ground source heat pumps can adapt to different climatic conditions and building types, and have a wide range of applications.

Economics of geothermal heat pumps

Although the initial investment of the heat pump uses geothermal energy for homes and other scenarios is high, its long-term energy saving effect is significant and can reduce operating costs. Especially in cold areas, ground source heat pump has high heat pump efficiency, low maintenance cost and good economic performance.

Environmental impact of ground source heat pumps

Ground source heat pump is a green energy technology with the following environmental advantages:

1. Reduce greenhouse gas emissions: Ground energy heat pump uses natural heat energy stored on the surface or underground, reducing the use of fossil fuels.

2. Improve energy efficiency: The high heat pump efficiency and waste heat recovery capabilities of gshp heat pump can reduce energy waste.

3. Reduce noise and pollutant emissions: Compared with traditional cogeneration technology, ground source heat pump has lower noise and pollutant emissions.

Geothermal Heating,Geothermal Air Conditioning,Geothermal Energy For Homes,Geothermal Heat Pump Air Conditioning,Ground Heat Pump

GUANGZHOU GENT NEW ENERGY TECHNOLOGY CO., LTD , https://www.gentgz.com

Posted on