In the simulation environment test equipment, the programmable constant temperature and humidity test chamber is widely used in the detection and research and development of heat, cold, dry and moisture resistance in the fields of electronics, electrics, auto parts, and metal products. Its main components are humidification, heating, refrigeration, and control systems. The main principle of humidification is to turn water into water and heat so that the humidity in the test chamber can be controlled. Therefore, the installation of the humidification system of the programmable constant temperature and humidity test box is actually the installation of the humidification water.
The installation method is as follows:
1. First, inject the recovery tank into pure water or distilled water (do not use tap water, etc., so as to avoid clogging during use, and the tester cannot operate normally), and add it to about nine minutes;
2. Check whether the maintenance valve is relevant (closed with the vertical direction of the water pipe);
3. After power supply is properly configured for about 3 minutes, please pay attention to the supply water tank and the water level of the water level controller. Always maintain more than half of the water level (see the observation port at the front and bottom of the machine).
4. When replenishing humidifying water, when the water level is insufficient, pure water or distilled water is injected into the water tank, and a small water pump is used to pump the tank to the water supply system for the automatic water circulation system.
Precautions:
1. Check whether the wet ball super wet protection switch of the programmable constant temperature and humidity test box is set to 150°C (this value is the safety protection range);
2, confirm whether the amount of water is sufficient;
3, confirm the cover of the tank is properly covered;
4. Make sure that the tank water is clean and free of debris;
5. Check whether the humidified gauze is not hardened or yellowed;
6, check the water level after 3 to 5 minutes after the humidification tank water supply, the bucket water needs to cover the humidification tube about 1 centimeter;
7. Whether the water in the humidifying tank is clean (The water in the humidifying tank should be drained regularly to keep the inside clean);
8. Confirmation of the drain pipe (whether the drain pipe is properly connected or the drain valve is closed)